Part Number Hot Search : 
MAX23701 KS007 FQB5N60 R3000 FSDM0765 MB90V AD9970 STZ8270C
Product Description
Full Text Search
 

To Download 03CK020-150 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  technical data sheet rpc-3.50 calibration kit lrl version 03CK020-150 rosenberger hochfrequenztechnik gmbh & co. kg p.o.box 1260 d-84526 tittmoning germany www.rosenberger.de tel. : +49 8684 18-0 fax : +49 8684 18-499 email : info@rosenberger.de page 1 / 3 dieses dokument ist urheberrechtlich geschtzt this document is protected by copyright rosenberger hochfrequenztechnik gmbh & co. kg rf_35/05.10/6.1 contents device part number remarks qty calibration option a 15 mm air line plug/jack 03s101-k015 l1 1 fc 20 mm air line plug/jack 03s101-k020 l2 1 fc 38.5 mm air line plug/jack 03s101-k038 l3 1 fc short circuit plug 03s12s-001d3 reflect standard 1 fc short circuit jack 03k12s-001d3 reflect standard 1 fc combi wrench 03w008-000 - 1 torque wrench 03w021-000 - 1 fc a. see declaration of calibration options for exp lanation. lrl calibrations without lowband loads are band lim ited. there are many different possibilities to cal ibrate a vna depending from the line length and the number of lines used during the calibration procedure. if two lines are used the third line can be used as ve rification standard. the following graphs show two possibilities using lrl with lowband loads. without lowband loads the lower band cannot be calibrated. 0 frequency range (2 bands) lowband loads l1 and l2 26.5 f in ghz 5 low band loads l1 and l 3 l1 and l 2 f in ghz 26.5 5 0 1 frequency range (3 bands)
technical data sheet rpc-3.50 calibration kit lrl version 03CK020-150 rosenberger hochfrequenztechnik gmbh & co. kg p.o.box 1260 d-84526 tittmoning germany www.rosenberger.de tel. : +49 8684 18-0 fax : +49 8684 18-499 email : info@rosenberger.de page 2 / 3 dieses dokument ist urheberrechtlich geschtzt this document is protected by copyright rosenberger hochfrequenztechnik gmbh & co. kg rf_35/05.10/6.1 documentation this kit is delivered with usb-stick standard definitions as data files for vector netwo rk anaylzer families pna (keysight/agilent) and zva (rohde&schwarz). calibration certificate as pdf-fil e. standard definitions cards printed standard definitions that can be used on ne arly all vector network analyzers. kit info card handling precautions and information for installing standard definitions on a vector network analyzer. calibration certificate details see declaration of calibration options operating manual electrical specifications this specification covers electrical key values for the main items of the calibration kit. specific da tasheets are available for each component among the part num ber. device frequency parameter specification shorts b (plug and jack) dc > 4 ghz > 8 ghz to to to 4 ghz 8 ghz 26.5 ghz error from nominal phase 1.0 1.5 2.0 precision air lines c 0.3 ghz > 4 ghz > 8 ghz to to to 4 ghz 8 ghz 26.5 ghz return loss 3 40 db 3 38 db 3 35 db b. the specifications for the shorts are given as a llowed deviation from nominal model as defined in c alibration certificate included with your kit. c. calculated value without warranty. the return lo ss specification includes the connector interfaces. the minimum frequency of the air lines is based on calculations of the imped ance change due to skin depth. refer to the calibra tion certificate included with your kit for the exact dimensions of your precision air lines.
technical data sheet rpc-3.50 calibration kit lrl version 03CK020-150 rosenberger hochfrequenztechnik gmbh & co. kg p.o.box 1260 d-84526 tittmoning germany www.rosenberger.de tel. : +49 8684 18-0 fax : +49 8684 18-499 email : info@rosenberger.de page 3 / 3 dieses dokument ist urheberrechtlich geschtzt this document is protected by copyright rosenberger hochfrequenztechnik gmbh & co. kg rf_35/05.10/6.1 declaration of calibration options factory calibration standard delivery for this kit includes a factory c alibration. the calibration certificate issued repo rts individual mechanical calibration results, traceabl e to national / international standards. model base d standard definitions are reported in an agilent, rohde & sch warz and anritsu compatible vna format. accredited calibration not available. for further, more detailed information see applicat ion note an001 on the rosenberger homepage. calibration interval recommendation 12 months recommended accessories - rosenberger test port adaptor - rosenberger gauge kit 03gk0ks-010 - rosenberger vna test cable kit and microwave cabl e assemblies - rosenberger calibration loads 03s150-c10s3 and 03 k150-c10s3 for further, more detailed information please visit our homepage www.rosenberger.com . draft date approved date rev. engineering change number name date martin moder 23.10.14 r. neuhauser 01.06.16 b00 16-0852 s. andorfer 01.06.16 while the information has been carefully compiled t o the best of our knowledge, nothing is intended as representation or warr anty on our part and no statement herein shal l be construed as recommendation to infringe existi ng patents. in the effort to improve our products, we reserve the right to make changes judg ed to be necessary.


▲Up To Search▲   

 
Price & Availability of 03CK020-150

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X